The best way to Install a Ceiling Fan Light Twin Dimmer Switch

One switch usually gives electricity that is only requiring one to utilize chains to select a lover pace, and to to show the lights on / off. It’s possible for you to install a ceiling fan-light dimmer that is twin switch to to use light intensity and the fan speed in the wall change area that is first. The change that is new does need a wire that is extra to to be able to operate to to split up the light from your fan.

Turn in the light change in your ceiling fan. The blades are turning as well as the lights are burning.

Find the 15- or 20- . Turn the breaker off to disconnect the electricity. The ceiling fan-lights will be off as well as the fan blades will stop turning when you flip off the breaker that is right.

Hold a non-contact voltage tester from the ceiling fan wall-switch cover plate. When electric power isn’t current in the switch the indicator bulb on the tester WOn’t light.

Remove the screws holding the cover plate. Touch the tester to the two black wires connected to the medial side of the ceiling fan change to assure the power is disconnected.

By by eliminating the two to four screws release the ceiling fan canopy in the hanging bracket on the ceiling. In order to test the wires connecting the ceiling fan to the wires in the lover electrical box, let the canopy relaxation from the ceiling fan motor.

Hold the tester from the black wires linked as well as a wire connector. Although you switched off off the breaker that is right, double check before disconnecting the wires for strength.

Untwist the connectors keeping the wires to the ceiling fan wires in the box. Lift the ceiling enthusiast in the hanging bracket and established it on a worksurface that is a reliable.

Release by by detatching the two screws keeping it, the ceiling enthusiast wall change from your wall. Loosen the two final screws on along side it of the swap so that you can release the wires that are black. Dispose of the unique ceiling enthusiast wall swap.

Bend the ends of the copper that is white, black and bare wires in the box in the ceiling right into a hook. Create a hook-in the end-of a size of 12-3 non-metallic . that is electrical Hook the wires in the ceiling box to the 123 NM cable together Wrap the wires until the 123 is in electrical tape securely connected to the wires in the ceiling.

Look in the box that held the ceiling lover change. Get the wire connectors keeping the copper wires and the wires. Untwist these connectors and pull the two sets of wires aside.

The black, white and bare copper wires that operate in the box in the wall in the ceiling to the box. Pull the wires from your box in the wall. Pull the 123 attached as you pull the wires This replaces the 122 with the new 123 NM cable.

Pull the cable till you expose a-T least 8″ of 123 NM cable a T the electrical box in the wall. Cut the tape from your electrical cable to produce the outdated 122 NM and discard it. Leave a-T least 8″ of cable uncovered in the ceiling box.

Insert the ends of the 12 2 NM cable in to the middle hole of a cable ripper. Squeeze the ripper’s handles together to rip open at least 6″ of exterior sheath on the cable ends. Use wire-cutters to slice the the sheath that is free and expose the four wires within the cable. Strip about 3/4 inch of insulation off each of the uncovered wires, utilizing wire strippers.

Place the ceiling enthusiast to the hanging bracket on the ceiling. Connect the black motor wire in the ceiling fanto the black wire in the box. Twist a wire connector onto the wires that are black to secure them. Repeat this relationship for the two wires that are white.

Twist a wire connector onto the green wire in the ceiling fan-to the copper grounding wire from your box to link the two wires. Connect the red wire that is remaining in the ceiling to the remaining mild fixture wire from your ceiling fan. With regards to the manufacturer, this wire could be black using a stripe, blue or black having a yellow stripe.

Slide the canopy within the hanging bracket. Secure it with the screws you eliminated formerly.

Reconnect the white wire within the box in the wall to the new wire that is white, utilizing a wire connector. Do the sam-e using the two copper wires in the box. Carefully drive the two sets of wires to the rear of the box.

Get the black electrical wire called “line” connected to the ceiling fanlight twin dimmer swap. Connect it to the unique wire from your wall box using an orange wire connector. Connect the black electrical wire in the dimmer called “load” to the new black electrical wire you pulled to the wall box with a different connector.

Connect the red electrical wire in the wall box to the remaining electrical wire on the swap defined as “light” using an ultimate orange wire connector.

Position the twin dimmer change in the wall box. Secure the bottom of the dimmer and also the top change with all the screws that was included with it to the wall box. Cover plate provided together with the dimmer change.

Turn the breaker to reconnect the electricity to the ceiling enthusiast.

See related